■ Demo— not a validated GxP system — synthetic data

Affinis

AFN-001773-01 · EGFR L858R/T790M

Approved · locked

CRV-2026-00413-012 · v1 · auto-fitPlates PL-2026-0413, PL-2026-0414 (n = 2 replicates)4PL · Levenberg–Marquardt · unweighted, log₁₀[C]

Curve 4 / 10 in batch

Response vs concentration

  • Rep. 1 · PL-0413
  • Rep. 2 · PL-0414
  • Masked
  • IC50 95 % CI
Response against concentration, EGFR L858R/T790M−10−9−8−7−6−50255075100log₁₀ [compound] (M)% inhibitionF13 on PL-2026-0413F14 on PL-2026-0413F15 on PL-2026-0413F16 on PL-2026-0413F17 on PL-2026-0413F18 on PL-2026-0413F19 on PL-2026-0413F20 on PL-2026-0413F21 on PL-2026-0413F22 on PL-2026-0413F13 on PL-2026-0414F14 on PL-2026-0414F15 on PL-2026-0414F16 on PL-2026-0414F17 on PL-2026-0414F18 on PL-2026-0414F19 on PL-2026-0414F20 on PL-2026-0414F21 on PL-2026-0414F22 on PL-2026-0414

Concentrations: 10-point, 1:3, 0.508 nM – 10.0 µMPoints used 20 / 20

Fit parameters — v1 · auto-fit

ParameterEstimate95 % CIConstraint
Top100.6 %[99.1, 102.1] %Free
Bottom7.8 %[5.4, 10.1] %Free
IC5025.6 nM[23.2, 28.2] nMFree
pIC507.59± 0.02 (SE)Derived
Hill slope (nH)1.04[0.94, 1.14]Free

R² 0.998RMSE 1.4 %df 16Fit engine 1.2.0 · 20 / 20 points

Review decision

IC50

25.6 nM

95 % CI 23.2–28.2 nM · pIC50 7.59

Electronically signed

mlaurent (mlaurent)

2026-11-04 17:40:00 UTC

Meaning: Approved — result valid for SAR use

record sha256 4667…2fa4

This result is immutable. A correction creates a new version with a mandatory reason and its own signature.

History

append-only
  1. v1 auto-fit createdsystem · 2026-11-04 17:05:40 UTCFit engine 1.2.0 · 20 / 20 points · no flags
  2. Re-authenticatedmlaurent · 2026-11-04 17:40:00 UTCPassword verified for signing
  3. Signed — Approvedmlaurent · 2026-11-04 17:40:00 UTCMeaning: Approved — result valid for SAR use · v1 · auto-fit · record hash sha256 4667…2fa4