■ Demo— not a validated GxP system — synthetic data

Affinis

AFN-003292-01 · EGFR L858R/T790M

Rejected

CRV-2026-00428-020 · v1 · auto-fitPlates PL-2026-0428, PL-2026-0429 (n = 2 replicates)4PL · Levenberg–Marquardt · unweighted, log₁₀[C]

Curve 4 / 10 in batch

Response vs concentration

  • Rep. 1 · PL-0428
  • Rep. 2 · PL-0429
  • Masked
  • IC50 95 % CI
Response against concentration, EGFR L858R/T790M−10−9−8−7−6−50255075100log₁₀ [compound] (M)% inhibitionJ13 on PL-2026-0428J14 on PL-2026-0428J15 on PL-2026-0428J16 on PL-2026-0428J17 on PL-2026-0428J18 on PL-2026-0428J19 on PL-2026-0428J20 on PL-2026-0428J21 on PL-2026-0428J22 on PL-2026-0428J13 on PL-2026-0429J14 on PL-2026-0429J15 on PL-2026-0429J16 on PL-2026-0429J17 on PL-2026-0429J18 on PL-2026-0429J19 on PL-2026-0429J20 on PL-2026-0429J21 on PL-2026-0429J22 on PL-2026-0429

Concentrations: 10-point, 1:3, 0.508 nM – 10.0 µMPoints used 20 / 20

Fit parameters — v1 · auto-fit

ParameterEstimate95 % CIConstraint
Top101.4 %[99.4, 103.5] %Free
Bottom4.8 %[3.2, 6.3] %Free
IC50144 nM[132, 157] nMFree
pIC506.84± 0.02 (SE)Derived
Hill slope (nH)1.14[1.04, 1.24]Free

R² 0.999RMSE 1.5 %df 16Fit engine 1.2.0 · 20 / 20 points

Review decision

IC50

144 nM

95 % CI 132–157 nM · pIC50 6.84

Rejected: Curve does not plateau — retest over a wider range

History

append-only
  1. v1 auto-fit createdsystem · 2026-11-04 17:05:40 UTCFit engine 1.2.0 · 20 / 20 points · no flags
  2. Rejectedmlaurent · 2026-11-04 18:10:00 UTC“Curve does not plateau — retest over a wider range” · v1 · auto-fit