■ Demo— not a validated GxP system — synthetic data

Affinis

AFN-003349-01 · EGFR L858R/T790M

Rejected

CRV-2026-00430-002 · v1 · auto-fitPlates PL-2026-0430, PL-2026-0431 (n = 2 replicates)4PL · Levenberg–Marquardt · unweighted, log₁₀[C]

Curve 8 / 10 in batch

Response vs concentration

  • Rep. 1 · PL-0430
  • Rep. 2 · PL-0431
  • Masked
  • IC50 95 % CI
Response against concentration, EGFR L858R/T790M−10−9−8−7−6−50255075100log₁₀ [compound] (M)% inhibitionA13 on PL-2026-0430A14 on PL-2026-0430A15 on PL-2026-0430A16 on PL-2026-0430A17 on PL-2026-0430A18 on PL-2026-0430A19 on PL-2026-0430A20 on PL-2026-0430A21 on PL-2026-0430A22 on PL-2026-0430A13 on PL-2026-0431A14 on PL-2026-0431A15 on PL-2026-0431A16 on PL-2026-0431A17 on PL-2026-0431A18 on PL-2026-0431A19 on PL-2026-0431A20 on PL-2026-0431A21 on PL-2026-0431A22 on PL-2026-0431

Concentrations: 10-point, 1:3, 0.508 nM – 10.0 µMPoints used 20 / 20

Fit parameters — v1 · auto-fit

ParameterEstimate95 % CIConstraint
Top99.6 %[95.4, 103.9] %Free
Bottom−0.5 %[−1.9, 0.9] %Free
IC50642 nM[564, 732] nMFree
pIC506.19± 0.03 (SE)Derived
Hill slope (nH)1.03[0.92, 1.15]Free

R² 0.998RMSE 1.6 %df 16Fit engine 1.2.0 · 20 / 20 points

Review decision

IC50

642 nM

95 % CI 564–732 nM · pIC50 6.19

Rejected: Curve does not plateau — retest over a wider range

History

append-only
  1. v1 auto-fit createdsystem · 2026-11-04 17:05:40 UTCFit engine 1.2.0 · 20 / 20 points · no flags
  2. Rejectedmlaurent · 2026-11-04 18:10:00 UTC“Curve does not plateau — retest over a wider range” · v1 · auto-fit