■ Demo— not a validated GxP system — synthetic data

Affinis

AFN-001345-01 · H1975 cells

Rejected

CRV-2026-00494-005 · v1 · auto-fitPlates PL-2026-0494 (n = 1 replicates)4PL · Levenberg–Marquardt · unweighted, log₁₀[C]

Curve 9 / 10 in batch

Response vs concentration

  • Rep. 1 · PL-0494
  • Masked
  • IC50 95 % CI
Response against concentration, H1975 cells−9−8−7−6−50255075100log₁₀ [compound] (M)% inhibitionE03 on PL-2026-0494E04 on PL-2026-0494E05 on PL-2026-0494E06 on PL-2026-0494E07 on PL-2026-0494E08 on PL-2026-0494E09 on PL-2026-0494E10 on PL-2026-0494

Concentrations: 8-point, 1:3, 4.57 nM – 10.0 µMPoints used 8 / 8

Fit parameters — v1 · auto-fit

ParameterEstimate95 % CIConstraint
Top102.5 %[99.6, 105.4] %Free
Bottom3.2 %[1.2, 5.3] %Free
IC50358 nM[324, 395] nMFree
pIC506.45± 0.02 (SE)Derived
Hill slope (nH)0.89[0.81, 0.98]Free

R² 1.000RMSE 0.5 %df 4Fit engine 1.2.0 · 8 / 8 points

Review decision

IC50

358 nM

95 % CI 324–395 nM · pIC50 6.45

Rejected: Signal drift across the plate, replicates disagree

History

append-only
  1. v1 auto-fit createdsystem · 2026-11-04 17:05:40 UTCFit engine 1.2.0 · 8 / 8 points · no flags
  2. Rejectedmlaurent · 2026-11-04 18:10:00 UTC“Signal drift across the plate, replicates disagree” · v1 · auto-fit