■ Demo— not a validated GxP system — synthetic data

Affinis

AFN-002125-01 · H1975 cells

Approved · locked

CRV-2026-00506-006 · v1 · auto-fitPlates PL-2026-0506 (n = 1 replicates)4PL · Levenberg–Marquardt · unweighted, log₁₀[C]

Curve 6 / 10 in batch

Response vs concentration

  • Rep. 1 · PL-0506
  • Masked
  • IC50 95 % CI
Response against concentration, H1975 cells−9−8−7−6−50255075100log₁₀ [compound] (M)% inhibitionF03 on PL-2026-0506F04 on PL-2026-0506F05 on PL-2026-0506F06 on PL-2026-0506F07 on PL-2026-0506F08 on PL-2026-0506F09 on PL-2026-0506F10 on PL-2026-0506

Concentrations: 8-point, 1:3, 4.57 nM – 10.0 µMPoints used 8 / 8

Fit parameters — v1 · auto-fit

ParameterEstimate95 % CIConstraint
Top117.6 %[34.0, 201.2] %Free
Bottom3.7 %[−4.2, 11.5] %Free
IC503.62 µM[0.411, 31.9] µMFree
pIC505.44± 0.34 (SE)Derived
Hill slope (nH)0.71[0.21, 1.22]Free

R² 0.994RMSE 2.0 %df 4Fit engine 1.2.0 · 8 / 8 points

Review decision

IC50

3.62 µM

95 % CI 0.411–31.9 µM · pIC50 5.44

Electronically signed

mlaurent (mlaurent)

2026-11-04 17:40:00 UTC

Meaning: Approved — result valid for SAR use

record sha256 1a36…71ae

This result is immutable. A correction creates a new version with a mandatory reason and its own signature.

History

append-only
  1. v1 auto-fit createdsystem · 2026-11-04 17:05:40 UTCFit engine 1.2.0 · 8 / 8 points · incompleteTop, wideCi
  2. Re-authenticatedmlaurent · 2026-11-04 17:40:00 UTCPassword verified for signing
  3. Signed — Approvedmlaurent · 2026-11-04 17:40:00 UTCMeaning: Approved — result valid for SAR use · v1 · auto-fit · record hash sha256 1a36…71ae