AFN-003182-01 · H1975 cells
Approved · lockedCRV-2026-00524-004 · v1 · auto-fitPlates PL-2026-0524 (n = 1 replicates)4PL · Levenberg–Marquardt · unweighted, log₁₀[C]
Curve 8 / 10 in batch
Response vs concentration
- Rep. 1 · PL-0524
- Masked
- IC50 95 % CI
Concentrations: 8-point, 1:3, 4.57 nM – 10.0 µMPoints used 8 / 8
Fit parameters — v1 · auto-fit
y = Bottom + (Top − Bottom) / (1 + 10^((log IC50 − x) · nH))| Parameter | Estimate | 95 % CI | Constraint |
|---|---|---|---|
| Top | 103.1 % | [87.9, 118.4] % | Free |
| Bottom | 7.6 % | [4.6, 10.7] % | Free |
| IC50 | 1.68 µM | [1.08, 2.60] µM | Free |
| pIC50 | 5.78 | ± 0.07 (SE) | Derived |
| Hill slope (nH) | 0.86 | [0.64, 1.07] | Free |
R² 0.999RMSE 0.9 %df 4Fit engine 1.2.0 · 8 / 8 points
Review decision
IC50
1.68 µM
95 % CI 1.08–2.60 µM · pIC50 5.78
Electronically signed
mlaurent (mlaurent)
2026-11-04 17:40:00 UTC
Meaning: Approved — result valid for SAR use
record sha256 e59d…3edf
This result is immutable. A correction creates a new version with a mandatory reason and its own signature.
History
append-only- v1 auto-fit createdsystem · 2026-11-04 17:05:40 UTCFit engine 1.2.0 · 8 / 8 points · incompleteTop
- Re-authenticatedmlaurent · 2026-11-04 17:40:00 UTCPassword verified for signing
- Signed — Approvedmlaurent · 2026-11-04 17:40:00 UTCMeaning: Approved — result valid for SAR use · v1 · auto-fit · record hash sha256 e59d…3edf