■ Demo— not a validated GxP system — synthetic data

Affinis

AFN-004036-01 · H1975 cells

Approved · locked

CRV-2026-00541-001 · v1 · auto-fitPlates PL-2026-0541 (n = 1 replicates)4PL · Levenberg–Marquardt · unweighted, log₁₀[C]

Curve 1 / 10 in batch

Response vs concentration

  • Rep. 1 · PL-0541
  • Masked
  • IC50 95 % CI
Response against concentration, H1975 cells−9−8−7−6−50255075100log₁₀ [compound] (M)% inhibitionA03 on PL-2026-0541A04 on PL-2026-0541A05 on PL-2026-0541A06 on PL-2026-0541A07 on PL-2026-0541A08 on PL-2026-0541A09 on PL-2026-0541A10 on PL-2026-0541

Concentrations: 8-point, 1:3, 4.57 nM – 10.0 µMPoints used 8 / 8

Fit parameters — v1 · auto-fit

ParameterEstimate95 % CIConstraint
Top97.2 %[86.8, 107.7] %Free
Bottom−0.7 %[−2.9, 1.4] %Free
IC501.88 µM[1.46, 2.42] µMFree
pIC505.73± 0.04 (SE)Derived
Hill slope (nH)1.13[0.90, 1.35]Free

R² 0.999RMSE 0.9 %df 4Fit engine 1.2.0 · 8 / 8 points

Review decision

IC50

1.88 µM

95 % CI 1.46–2.42 µM · pIC50 5.73

Electronically signed

mlaurent (mlaurent)

2026-11-04 17:40:00 UTC

Meaning: Approved — result valid for SAR use

record sha256 b274…904e

This result is immutable. A correction creates a new version with a mandatory reason and its own signature.

History

append-only
  1. v1 auto-fit createdsystem · 2026-11-04 17:05:40 UTCFit engine 1.2.0 · 8 / 8 points · incompleteTop
  2. Re-authenticatedmlaurent · 2026-11-04 17:40:00 UTCPassword verified for signing
  3. Signed — Approvedmlaurent · 2026-11-04 17:40:00 UTCMeaning: Approved — result valid for SAR use · v1 · auto-fit · record hash sha256 b274…904e